Energy Data Input Date of Inspection 10­Apr­2013 Full Address 114, Dedworth Road WINDSOR SL4 5BD Postcode Home Inspector`s Name Mr Alex Smith Home Inspector`s Membership No data has been entered E­mail Address trial00603@nesltd.co.uk Report Reference Number 3605542 Energy Data Input GENERAL DETAILS Property type House Detachment type Semi detached Measurement type Internal Number of storeys 2 Terrain type Suburban Number of extensions 1 Mains gas available Yes Total habitable rooms 9 Any unheated rooms No Energy Data Input CONSTRUCTION Main age 1930 to 1949 Ext 1 age 1996 to 2002 Main roof Pitched (slates or tiles) access to loft unknown insulation Ext 1 roof Flat roof unknown insulation Main wall Solid brick ­ as built insulation ( 200mm) Ext 1 wall System build ­ as built insulation ( 250mm) Main floor Semi exposed to partially heated space Ext 1 floor Semi exposed to unheated space, unknown construction as built insulation Energy Data Input ALTERNATIVE WALL Energy Data Input DIMENSIONS Area (m²) Height (m) HLP (m) Main Floor 1 53.6 2.42 30 Main Floor 0 53.6 2.56 27.1 Ext 1 Floor 0 9.28 2.33 9.3 Energy Data Input ROOF ROOMS Main roof room 1996 to 2002, unknown insulation Floor Area (m²) 26.6 Extended No Energy Data Input OPENINGS & VENTILATION Total glazed area Normal Proportion double glazed 100 Double glazing installed Double glazed pre 2002 Doors 2 Draughtproofing 100 Open fireplaces 0 Mechanical ventilation Yes Supply and extract No Air conditioning No Page 2 of 4 Energy Data Input SPACE HEATING Electricity meter Dual System number 1 Heating fraction 100 Type Boiler system Boiler type Regular boiler Fan flue No fan flue Flue type Open flue Fuel Mains gas Primary system Code 101 ­ Regular non­condensing with automatic ignition Controls Programmer and room thermostat Emitter Radiators Secondary fuel None Secondary system None Energy Data Input WATER HEATING Water Heating type From single immersion heater (Electricity) Water heating storage Normal sized cylinder (90­130 litres) with 25mm spray foam insulation Cylinder thermostat Yes Rooms with bath and/or ANY shower MIXER shower AND bath 2 0 MIXER shower only 0 Energy Data Input CONSERVATORIES, RENEWABLES & LIGHTING Conservatory type Separated no fixed heaters Solar hot water heating No Wind turbine No Photovoltaic array No Low energy lights 0 of 18 lights are low energy Energy Data Input Page 3 of 4 ADDENDUM Access Issues No High Exposure No Narrow Cavity No Energy Data Input SECTIONS WHERE DEFAULTS OVERWRITTEN Page 4 of 4